ZY POWER
ProjectsFactoryDownloads
Contact
Get Quote
  1. Home
  2. /Products
  3. /Power Transformer
  4. /11kV Transformer

Transformer Voltage Landing Page

11kV Transformer

Select a 11kV transformer for urban distribution, commercial feeders, small industrial plants and package substations. This page helps EPC teams and buyers define the technical inputs required for a reliable transformer quotation.

Send RFQDownload Datasheet
11kV Transformer

Primary Voltage

11kV

Transformer Types

Dry type, oil immersed or package substation transformer

Secondary Voltage

0.4kV, 0.69kV, 6.3kV, 10kV or project-defined output

Frequency

50Hz or 60Hz

Product Overview

Engineering Selection Context

11kV transformers are used to adapt medium-voltage utility or plant distribution networks to the required low-voltage or secondary medium-voltage level.

ZY POWER transformer pages are aligned to the documented power transformer portfolio: S11/S13/S20/S22 oil-immersed transformers and SCB13/SCB14/SCB18 cast-resin dry type transformers for 30-3,150kVA distribution applications.

The correct selection depends on load capacity, installation environment, fire-risk policy, cooling method, impedance, vector group, short-circuit condition and local grid requirements.

Ziyao Power can prepare dry type, oil immersed or prefabricated substation transformer proposals when the buyer provides the single-line diagram or transformer schedule.

Technical Specifications

Key Data Required Before Quotation

These values should be confirmed against the single-line diagram, tender document and site conditions.

Rated Voltage11kV primary, secondary voltage by project design
Rated Capacity30kVA to 3150kVA documented distribution range; larger ratings by project review
Frequency50Hz or 60Hz
Transformer TypeDry type for indoor use, oil immersed for outdoor or utility service
Vector GroupDyn11, Yyn0 or specified by grid design
CoolingAN/AF for dry type, ONAN for oil immersed type
Core Material NoteS13/S20/S22 pages use silicon steel / low-loss oil immersed wording; amorphous alloy wording is kept for SH15/SBH15/SCBH15 series only
Protection LevelIP enclosure for dry type, outdoor tank or kiosk enclosure for oil type
Installation TypeIndoor room, outdoor pad, package substation or utility bay
StandardIEC 60076 series, IEC 60076-11 for dry type, IEC 60076-2 for temperature rise, GB 1094 / GB 20052 where specified

Construction & Materials

Build Details Buyers Should Confirm

Material decisions influence loss level, thermal behavior, footprint, maintenance and approval documents.

Silicon steel core design selected for the specified loss level and service duty.

Dry type cast-resin or oil immersed winding structure selected according to installation environment.

Tap changer, terminals, rollers, lifting points and grounding terminals configured to project drawings.

Optional enclosure, temperature monitor, protection relay interface and cable box by installation layout.

Applications

Where This Page Fits

urban distribution, commercial feeders, small industrial plants and package substations

Utility distribution substations and industrial plant incoming feeders.

Commercial buildings, renewable projects and infrastructure power supply systems.

Package substations requiring transformer, MV switchgear and LV switchgear coordination.

Standards & Compliance

Documents for Engineering Review

IEC 60076 power transformer standard series.

Routine factory testing before shipment.

Project-specific drawing, datasheet and test certificate package.

Local grid or tender standard can be reviewed during quotation.

FAQ

Procurement Questions

What secondary voltage can be supplied for a 11kV transformer?

Common secondary voltages include 0.4kV, 0.69kV, 6.3kV and 10kV, but the final value should follow the load system and grid connection design.

Should a 11kV transformer be dry type or oil immersed?

Dry type is usually selected for indoor fire-safe installations. Oil immersed transformers are often preferred for outdoor utility, solar farm or higher-capacity distribution projects.

What capacity should be selected?

Capacity should be based on connected load, demand factor, future expansion, ambient temperature and allowable loading policy. A load schedule is better than selecting only by transformer name.

Which vector group is most common?

Dyn11 is common in many distribution projects, while other vector groups may be required by local grid rules or parallel operation conditions.

Can Ziyao Power supply transformer with switchgear?

Yes. Transformer, MV switchgear, LV switchgear and prefabricated substation packages can be coordinated for EPC projects.

What should be included in the RFQ?

Include voltage ratio, capacity, frequency, phase, vector group, impedance, installation environment, enclosure requirement, accessories, standards and destination country.

Are 50Hz and 60Hz designs both available?

Yes. The frequency must be confirmed at RFQ stage because it affects magnetic design, losses and temperature rise.

What documents are provided for engineering approval?

Typical documents include technical datasheet, outline drawing, wiring diagram, test report, nameplate and packing list.

RFQ CTA

Send your specification for engineering review

Attach a transformer schedule, single-line diagram, switchgear drawing or load list. Our team will match the product configuration to voltage, capacity, installation and approval requirements.

Request Quotation

Related Products

Continue Product Selection

SCB13 Dry Type Transformer

Cast-resin distribution transformer for indoor power rooms and commercial buildings.

View product

SCB14 Dry Type Transformer

Higher-efficiency dry type transformer option for long operating hours.

View product

Power Transformers

Dry type, oil immersed and amorphous alloy transformer systems.

View product

S22-M Oil Immersed Transformer

High-efficiency oil immersed distribution transformer for outdoor and utility use.

View product

Downloads

Transformer Selection GuideUse the selection guide to prepare voltage ratio, capacity, impedance and enclosure notes before RFQ.SCB13 Dry Type DatasheetReference dry type transformer datasheet for engineering review.

Related Technical Articles

Dry-Type Transformer Selection GuideSelection notes for epoxy cast-resin dry type transformers.SCB13 Transformer Selection GuideRFQ checklist and engineering selection factors for SCB13 series.Transformer BasicsCore transformer sizing, voltage and cooling concepts.

Products

  • Power Transformers
  • Substations
  • Medium Voltage Switchgear
  • Low Voltage Switchgear
  • Circuit Breakers
  • Instrument Transformers
  • Power Cables
  • Renewable Energy Solutions
  • Metering Solutions

Solutions

  • Power Generation
  • Industrial Plants
  • Utility Distribution
  • Renewable Energy

Support

  • Downloads
  • Knowledge Center
  • FAQ
  • Inquiry

Company

  • Company Profile
  • Factory Tour
  • Projects
  • Contact

Contact

  • sales@ziyaopower.com
  • WhatsApp: +86 151 5609 3235
  • +86 151 5609 3235
  • LinkedIn

Copyright 2026 ZY POWER. All rights reserved.

Zhejiang, China