Circuit Breakers & Components
Low-voltage and medium-voltage circuit breakers, protection relays, and switchgear components.
Available Products
Circuit Breakers & Components Catalog

DW45-200A/3P
DW45 Intelligent Air Circuit Breaker 200A 3P
DW45 series intelligent air circuit breaker (ACB) rated 200A, 3P, 400/690V AC, breaking capacity 65kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-200A/4P
DW45 Intelligent Air Circuit Breaker 200A 4P
DW45 series intelligent air circuit breaker (ACB) rated 200A, 4P, 400/690V AC, breaking capacity 65kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-400A/3P
DW45 Intelligent Air Circuit Breaker 400A 3P
DW45 series intelligent air circuit breaker (ACB) rated 400A, 3P, 400/690V AC, breaking capacity 65kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-400A/4P
DW45 Intelligent Air Circuit Breaker 400A 4P
DW45 series intelligent air circuit breaker (ACB) rated 400A, 4P, 400/690V AC, breaking capacity 65kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-630A/3P
DW45 Intelligent Air Circuit Breaker 630A 3P
DW45 series intelligent air circuit breaker (ACB) rated 630A, 3P, 400/690V AC, breaking capacity 65kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-630A/4P
DW45 Intelligent Air Circuit Breaker 630A 4P
DW45 series intelligent air circuit breaker (ACB) rated 630A, 4P, 400/690V AC, breaking capacity 65kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-800A/3P
DW45 Intelligent Air Circuit Breaker 800A 3P
DW45 series intelligent air circuit breaker (ACB) rated 800A, 3P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-800A/4P
DW45 Intelligent Air Circuit Breaker 800A 4P
DW45 series intelligent air circuit breaker (ACB) rated 800A, 4P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-1000A/3P
DW45 Intelligent Air Circuit Breaker 1000A 3P
DW45 series intelligent air circuit breaker (ACB) rated 1000A, 3P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-1000A/4P
DW45 Intelligent Air Circuit Breaker 1000A 4P
DW45 series intelligent air circuit breaker (ACB) rated 1000A, 4P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-1250A/3P
DW45 Intelligent Air Circuit Breaker 1250A 3P
DW45 series intelligent air circuit breaker (ACB) rated 1250A, 3P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-1250A/4P
DW45 Intelligent Air Circuit Breaker 1250A 4P
DW45 series intelligent air circuit breaker (ACB) rated 1250A, 4P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-1600A/3P
DW45 Intelligent Air Circuit Breaker 1600A 3P
DW45 series intelligent air circuit breaker (ACB) rated 1600A, 3P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-1600A/4P
DW45 Intelligent Air Circuit Breaker 1600A 4P
DW45 series intelligent air circuit breaker (ACB) rated 1600A, 4P, 400/690V AC, breaking capacity 80kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-2000A/3P
DW45 Intelligent Air Circuit Breaker 2000A 3P
DW45 series intelligent air circuit breaker (ACB) rated 2000A, 3P, 400/690V AC, breaking capacity 100kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-2000A/4P
DW45 Intelligent Air Circuit Breaker 2000A 4P
DW45 series intelligent air circuit breaker (ACB) rated 2000A, 4P, 400/690V AC, breaking capacity 100kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-2500A/3P
DW45 Intelligent Air Circuit Breaker 2500A 3P
DW45 series intelligent air circuit breaker (ACB) rated 2500A, 3P, 400/690V AC, breaking capacity 100kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-2500A/4P
DW45 Intelligent Air Circuit Breaker 2500A 4P
DW45 series intelligent air circuit breaker (ACB) rated 2500A, 4P, 400/690V AC, breaking capacity 100kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-3200A/3P
DW45 Intelligent Air Circuit Breaker 3200A 3P
DW45 series intelligent air circuit breaker (ACB) rated 3200A, 3P, 400/690V AC, breaking capacity 100kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
DW45-3200A/4P
DW45 Intelligent Air Circuit Breaker 3200A 4P
DW45 series intelligent air circuit breaker (ACB) rated 3200A, 4P, 400/690V AC, breaking capacity 100kA. Microprocessor-based trip unit with LCD display, LSIG-N protection, Modbus communication optional. Draw-out and fixed mounting available. IEC 60947-2 certified for main distribution protection.
View details
CM1-16H/3300
CM1 Molded Case Circuit Breaker (MCCB) 16A 3P
CM1 series molded case circuit breaker (MCCB) rated 16A, 3P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-16H/4300
CM1 Molded Case Circuit Breaker (MCCB) 16A 4P
CM1 series molded case circuit breaker (MCCB) rated 16A, 4P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-25H/3300
CM1 Molded Case Circuit Breaker (MCCB) 25A 3P
CM1 series molded case circuit breaker (MCCB) rated 25A, 3P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-25H/4300
CM1 Molded Case Circuit Breaker (MCCB) 25A 4P
CM1 series molded case circuit breaker (MCCB) rated 25A, 4P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-32H/3300
CM1 Molded Case Circuit Breaker (MCCB) 32A 3P
CM1 series molded case circuit breaker (MCCB) rated 32A, 3P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-32H/4300
CM1 Molded Case Circuit Breaker (MCCB) 32A 4P
CM1 series molded case circuit breaker (MCCB) rated 32A, 4P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-40H/3300
CM1 Molded Case Circuit Breaker (MCCB) 40A 3P
CM1 series molded case circuit breaker (MCCB) rated 40A, 3P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-40H/4300
CM1 Molded Case Circuit Breaker (MCCB) 40A 4P
CM1 series molded case circuit breaker (MCCB) rated 40A, 4P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-50H/3300
CM1 Molded Case Circuit Breaker (MCCB) 50A 3P
CM1 series molded case circuit breaker (MCCB) rated 50A, 3P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-50H/4300
CM1 Molded Case Circuit Breaker (MCCB) 50A 4P
CM1 series molded case circuit breaker (MCCB) rated 50A, 4P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-63H/3300
CM1 Molded Case Circuit Breaker (MCCB) 63A 3P
CM1 series molded case circuit breaker (MCCB) rated 63A, 3P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-63H/4300
CM1 Molded Case Circuit Breaker (MCCB) 63A 4P
CM1 series molded case circuit breaker (MCCB) rated 63A, 4P, 400/690V AC, breaking capacity 25kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-80H/3300
CM1 Molded Case Circuit Breaker (MCCB) 80A 3P
CM1 series molded case circuit breaker (MCCB) rated 80A, 3P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-80H/4300
CM1 Molded Case Circuit Breaker (MCCB) 80A 4P
CM1 series molded case circuit breaker (MCCB) rated 80A, 4P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-100H/3300
CM1 Molded Case Circuit Breaker (MCCB) 100A 3P
CM1 series molded case circuit breaker (MCCB) rated 100A, 3P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-100H/4300
CM1 Molded Case Circuit Breaker (MCCB) 100A 4P
CM1 series molded case circuit breaker (MCCB) rated 100A, 4P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-125H/3300
CM1 Molded Case Circuit Breaker (MCCB) 125A 3P
CM1 series molded case circuit breaker (MCCB) rated 125A, 3P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-125H/4300
CM1 Molded Case Circuit Breaker (MCCB) 125A 4P
CM1 series molded case circuit breaker (MCCB) rated 125A, 4P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-160H/3300
CM1 Molded Case Circuit Breaker (MCCB) 160A 3P
CM1 series molded case circuit breaker (MCCB) rated 160A, 3P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-160H/4300
CM1 Molded Case Circuit Breaker (MCCB) 160A 4P
CM1 series molded case circuit breaker (MCCB) rated 160A, 4P, 400/690V AC, breaking capacity 36kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-200H/3300
CM1 Molded Case Circuit Breaker (MCCB) 200A 3P
CM1 series molded case circuit breaker (MCCB) rated 200A, 3P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-200H/4300
CM1 Molded Case Circuit Breaker (MCCB) 200A 4P
CM1 series molded case circuit breaker (MCCB) rated 200A, 4P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-250H/3300
CM1 Molded Case Circuit Breaker (MCCB) 250A 3P
CM1 series molded case circuit breaker (MCCB) rated 250A, 3P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-250H/4300
CM1 Molded Case Circuit Breaker (MCCB) 250A 4P
CM1 series molded case circuit breaker (MCCB) rated 250A, 4P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-315H/3300
CM1 Molded Case Circuit Breaker (MCCB) 315A 3P
CM1 series molded case circuit breaker (MCCB) rated 315A, 3P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-315H/4300
CM1 Molded Case Circuit Breaker (MCCB) 315A 4P
CM1 series molded case circuit breaker (MCCB) rated 315A, 4P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-400H/3300
CM1 Molded Case Circuit Breaker (MCCB) 400A 3P
CM1 series molded case circuit breaker (MCCB) rated 400A, 3P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-400H/4300
CM1 Molded Case Circuit Breaker (MCCB) 400A 4P
CM1 series molded case circuit breaker (MCCB) rated 400A, 4P, 400/690V AC, breaking capacity 50kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-630H/3300
CM1 Molded Case Circuit Breaker (MCCB) 630A 3P
CM1 series molded case circuit breaker (MCCB) rated 630A, 3P, 400/690V AC, breaking capacity 70kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-630H/4300
CM1 Molded Case Circuit Breaker (MCCB) 630A 4P
CM1 series molded case circuit breaker (MCCB) rated 630A, 4P, 400/690V AC, breaking capacity 70kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-800H/3300
CM1 Molded Case Circuit Breaker (MCCB) 800A 3P
CM1 series molded case circuit breaker (MCCB) rated 800A, 3P, 400/690V AC, breaking capacity 70kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
CM1-800H/4300
CM1 Molded Case Circuit Breaker (MCCB) 800A 4P
CM1 series molded case circuit breaker (MCCB) rated 800A, 4P, 400/690V AC, breaking capacity 70kA. Thermal-magnetic trip unit with adjustable overload and fixed short-circuit protection. Compact design, DIN-rail or panel mounting. IEC 60947-2 certified for feeder and motor protection.
View details
ZN85-40.5/1250-25
ZN85-40.5 Indoor Vacuum Circuit Breaker 1250A 25kA
ZN85-40.5 indoor high voltage vacuum circuit breaker, rated 40.5kV 1250A 25kA. Handcart type for KYN61 switchgear. Maintenance-free vacuum interrupter with 10,000 mechanical operation life. IEC 62271-100 certified.
View details
ZN85-40.5/1250-31.5
ZN85-40.5 Indoor Vacuum Circuit Breaker 1250A 31.5kA
ZN85-40.5 indoor high voltage vacuum circuit breaker, rated 40.5kV 1250A 31.5kA. Handcart type for KYN61 switchgear. Maintenance-free vacuum interrupter with 10,000 mechanical operation life. IEC 62271-100 certified.
View details
ZN85-40.5/1600-25
ZN85-40.5 Indoor Vacuum Circuit Breaker 1600A 25kA
ZN85-40.5 indoor high voltage vacuum circuit breaker, rated 40.5kV 1600A 25kA. Handcart type for KYN61 switchgear. Maintenance-free vacuum interrupter with 10,000 mechanical operation life. IEC 62271-100 certified.
View details
ZN85-40.5/1600-31.5
ZN85-40.5 Indoor Vacuum Circuit Breaker 1600A 31.5kA
ZN85-40.5 indoor high voltage vacuum circuit breaker, rated 40.5kV 1600A 31.5kA. Handcart type for KYN61 switchgear. Maintenance-free vacuum interrupter with 10,000 mechanical operation life. IEC 62271-100 certified.
View details
ZN85-40.5/2000-25
ZN85-40.5 Indoor Vacuum Circuit Breaker 2000A 25kA
ZN85-40.5 indoor high voltage vacuum circuit breaker, rated 40.5kV 2000A 25kA. Handcart type for KYN61 switchgear. Maintenance-free vacuum interrupter with 10,000 mechanical operation life. IEC 62271-100 certified.
View details
ZN85-40.5/2000-31.5
ZN85-40.5 Indoor Vacuum Circuit Breaker 2000A 31.5kA
ZN85-40.5 indoor high voltage vacuum circuit breaker, rated 40.5kV 2000A 31.5kA. Handcart type for KYN61 switchgear. Maintenance-free vacuum interrupter with 10,000 mechanical operation life. IEC 62271-100 certified.
View details
VS1-12/630-25
VS1-12 Indoor Vacuum Circuit Breaker 630A 25kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 630A 25kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/1250-25
VS1-12 Indoor Vacuum Circuit Breaker 1250A 25kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 1250A 25kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/1250-31.5
VS1-12 Indoor Vacuum Circuit Breaker 1250A 31.5kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 1250A 31.5kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/1600-31.5
VS1-12 Indoor Vacuum Circuit Breaker 1600A 31.5kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 1600A 31.5kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/1600-40
VS1-12 Indoor Vacuum Circuit Breaker 1600A 40kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 1600A 40kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/2000-31.5
VS1-12 Indoor Vacuum Circuit Breaker 2000A 31.5kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 2000A 31.5kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/2000-40
VS1-12 Indoor Vacuum Circuit Breaker 2000A 40kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 2000A 40kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details
VS1-12/3150-40
VS1-12 Indoor Vacuum Circuit Breaker 3150A 40kA
VS1-12 indoor high voltage vacuum circuit breaker, rated 12kV 3150A 40kA. Handcart type for KYN28A (KYN44) switchgear. Spring operating mechanism, maintenance-free vacuum interrupter with 30,000 mechanical operation life. IEC 62271-100 certified for power distribution and motor starting.
View details